20-40KA 2P AC SPD
Produkta apraksts
Maiņstrāvas SPD ir piemēroti izmantots TT, TN-S, TN-C, IT, TN-CS uc barošanas sistēmās AC 50/60Hz,<380V, installation om the joint of LPZ1 or LPZ2 and LPZ3, it adopts 35mm standard rail, there is a failure release mounted in the module of surge protection device. When the SPD fails in breakdown for over-hart and over-current, the failure release will help electric equipment separate from the power supply system and give the indication signal, green means normal, red means abnormal, it also could be replaced for the module when has operating voltage.
Tehniskie parametri | FSP-A | |||||
Nominālais darba spriegums Un(V~) | 380V/220V | |||||
Maksimālais nepārtrauktas darbības spriegums Uc(V~) | 275V | 320V | 385V | 385V | 385V | 420V |
Sprieguma aizsardzība Level Up(V~)kV | Mazāks vai vienāds ar 1.0 | Mazāks vai vienāds ar 1,2 | Mazāks vai vienāds ar 1,8 | Mazāks vai vienāds ar 2.0 | Mazāks vai vienāds ar 2.2 | Mazāks vai vienāds ar 2,8 |
Nominālā izlādes strāva ln (8/20s)kA | 5 | 10 | 20 | 30 | 40 | 60 |
Maksimālā izlādes strāva lmax(8/20s)kA | 10 | 20 | 40 | 60 | 80 | 100 |
Atbildes laiks (ns) | <25 | |||||
Testa standarts | IEC61643.1, GB18802.1 | |||||
Darbības vide (grādi) | -40 grāds ~ plus 85 grādi | |||||
Maksimālā savienojuma līnija | 35 mm2 cietā stieples/35 mm2 dzīslu vara līnija | |||||
Ieteicamā savienojuma līnija | 16 mm2 cietā stieples/25 mm2 dzīslu vara līnija | |||||
Uzstādīšana | Standarta sliede 35 mm | |||||
Ārējā pārklājuma materiāls | Degdrošs neilons | |||||